40A Automatic Transfer Switch (ATS)

Type PC ATSE (Contactor) Conforms to: BS EN 60947-6-1:2005 and later amendments BS EN 60947-1
Availability: Built to order - current lead-time is 2-3 days.
SKU: CS-R40
Manufacturer part number: CS-R40
Delivery date: 1-2 days
Manufacturer: IO Automation Limited
*
£567.64 excl VAT

Automatic transfer between two supplies

  • IP66 mild steel enclosure
  • Bottom cable entry/exit
  • 40A rated AC1 contactors
  • Finder phase monitoring relay
  • Volt-free contacts for supply on load

 

Type PC ATSE (Contactor) 
Conforms to:
BS EN 60947-6-1:2005 and later amendments
BS EN 60947-1.

Function

Mains Failure (loss of phase(s) ).
    
1. Supply 1 contactor drops out.
2. Timer TD2 (range of 0.3 s - 30 hrs) activates for transfer delay time
3. After delay Supply 2 contactor engages to supply the load

Mains out of limits (under/over voltage, asymmetry).

1. Phase monitoring relay timer activates
2. If monitored values still out of limits Supply 1 contactor drops out.
3. Timer TD2 (range of 0.3 s - 30 hrs) activates for transfer delay time
4. After delay Supply 2 contactor engages to supply the load

On Return of Supply 1.

1. Phase monitoring relay and relay R1 activate
2. Supply 2 contactor drops out
3. Timer TD1 (range of 0.3 s - 30 hrs) activates for transfer delay
4. Supply 1 contactor activates to supply the load


Manual / Auto Switch.
    
Man Mode. Switches over to Supply 2 from Supply 1
Auto Mode. Supply 1 active unless phase failure conditions are present.

Automatic transfer between two supplies

  • IP66 mild steel enclosure
  • Bottom cable entry/exit
  • 40A rated AC1 contactors
  • Finder phase monitoring relay
  • Volt-free contacts for supply on load

 

Type PC ATSE (Contactor) 
Conforms to:
BS EN 60947-6-1:2005 and later amendments
BS EN 60947-1.

Function

Mains Failure (loss of phase(s) ).
    
1. Supply 1 contactor drops out.
2. Timer TD2 (range of 0.3 s - 30 hrs) activates for transfer delay time
3. After delay Supply 2 contactor engages to supply the load

Mains out of limits (under/over voltage, asymmetry).

1. Phase monitoring relay timer activates
2. If monitored values still out of limits Supply 1 contactor drops out.
3. Timer TD2 (range of 0.3 s - 30 hrs) activates for transfer delay time
4. After delay Supply 2 contactor engages to supply the load

On Return of Supply 1.

1. Phase monitoring relay and relay R1 activate
2. Supply 2 contactor drops out
3. Timer TD1 (range of 0.3 s - 30 hrs) activates for transfer delay
4. Supply 1 contactor activates to supply the load


Manual / Auto Switch.
    
Man Mode. Switches over to Supply 2 from Supply 1
Auto Mode. Supply 1 active unless phase failure conditions are present.

Products specifications
Attribute name Attribute value
Dimensions (height x width x depth) 500x400x210mm
ATS Specification
Rating (AC1) 40A
Cable Entry Bottom
Cable Exit Bottom